DLF10GS Heavy-Duty Retaining Walls

Smarter design and higher capacity with our heavy-duty retaining wall system.

What Makes Our Walls Different

The DLF10GS is our most robust L-shaped retaining wall system, designed to withstand higher loads and harsher conditions.

Quick to install and simple to use, the DLF10GS delivers outstanding performance without overengineering.

With a surcharge capacity of up to 25 kN/m², it’s ideal for projects where strength matters – from retained access roads to flood protection schemes and large-scale residential developments.

  • Rapid installation – up to 80 metres per day with a standard team and lifting equipment
  • Easy to install – units are delivered ready to place with no fixings or drilling required
  • 25 kN/m² surcharge capacity – designed for heavy-duty performance without increasing wall thickness.
  • HGV loading compatible – perfect for vehicle access areas, loading bays, and retained roads.
  • 17 height options – ranging from 0.5m to 4.5m in 250mm increments, with heeled versions available.
  • Reliable stock availability – with fast quoting and short lead times.
  • Eurocode compliant – designed to EN 1990, 1991, 1992 and 1997; CE marked to EN 15258

See The DLF10GS From Every Angle

Our 3D renders let you explore key features of the precast retaining walls, including lifting points, tongue-and-groove joints, chamfered edges and the bevelled top.

Rotate, zoom, and inspect the product in detail before you specify or buy.

Click the 3D button to launch the interactive product viewer

Smarter Details That Make Your Job Easier

Annotated render of CLF10GS precast retaining wall
Icon for bevelled top edge on precast retaining walls

Bevelled 100mm Top

For clean visual lines and secure handrail installation

Icon for chamfered wall edges

Chamfered Edges

For neat, easy joint sealing in bunds and clamps

Icon for interlocking concrete wall joints

Tongue & Groove Joint

For faster alignment and improved wall continuity

Icon for product quality

Self-Compacting Concrete

For a smooth, consistent honeycomb-free finish

Icon for cast-in pin anchors

Cast-In Lifting Anchors

For safe, quick and predictable handling

DLF10GS(Z) Retaining Wall With Heel

Our heeled variant is ideal for lower bearing capacity sites or variable ground conditions. Explore the rear heel detail in this interactive 3D model to understand how it spreads load more effectively.

View product features, heel extension, and overall geometry in full detail.

Click the 3D button to launch the interactive product viewer

Built For Groundworks, Backed By Engineering

We’ve taken everything that matters on site – installation speed, product quality, and structural performance and refined the design to make your job easier. DLF10GS gives you a smarter way to build retaining walls, with the engineering detail to back it up.

Bund wall retaining walls

DLF10GS Retaining Wall - Technical Specification

Surcharge Capacity 25 kN/m2
Design Life 50 Years
Concrete Grade C60/75 (self-compacting)
Exposure Classes XC4, XD3, XS3, XF4 (EN 206), others available on request
Reinforcement B500B as standard, alternative grades available on request
Unit Weight Varies by height and length - see product datasheets
Finish Smooth mould finish to all visible faces, with chamfered and bevelled edges
Connection Tongue and groove, no fixings needed
Installation Speed Typically installed at 80m/day with a 3-person team
Certification CE marked (EN 15258)

The DLF10GS Product Range

  • Units listed below are 2m long, they are also available in 1m lengths if lighter units are required.
  • Corner sections are available across the full height range.
  • For dimensions, weights and details on heeled variants CLF10GS(Z), please refer to the relevant datasheets below.
Heavy-duty retaining walls for storage yard
Product Code Height (mm) Length (mm) Width (mm) Weight (kg) Lifting Shackles
CLF10GS 50x200 500 2000 350 385 2 x 2.5T
CLF10GS 75x200 750 2000 600 625 2 x 2.5T
CLF10GS 100x200 1000 2000 600 745 2 x 2.5T
CLF10GS 125x200 1250 2000 850 995 2 x 2.5T
CLF10GS 150x200 1500 2000 850 1115 2 x 2.5T
DLF10GS 175x200 1750 2000 1150 1560 2 x 2.5T
DLF10GS 200x200 2000 2000 1150 1685 2 x 2.5T
DLF10GS 225x200 2250 2000 1350 2330 2 x 2.5T
DLF10GS 250x200 2500 2000 1350 2445 2 x 2.5T
DLF10GS 275x200 2750 2000 1600 3090 2 x 2.5T
DLF10GS 300x200 3000 2000 1600 3210 2 x 2.5T
DLF10GS 325x200 3250 2000 1850 3990 2 x 5T
DLF10GS 350x200 3500 2000 1850 4110 2 x 5T
DLF10GS 375x200 3750 2000 2100 5225 2 x 5T
DLF10GS 400x200 4000 2000 2100 5375 2 x 5T
DLF10GS 425x200 4250 2000 2350 6685 2 x 10T
DLF10GS 450x200 4500 2000 2350 6810 2 x 10T

We had just under 800 metres of precast retaining walls delivered to site within a short period. The quality of the units is excellent, with a very consistent finish. A job well done in tight time constraints.

Steve Ripley – Pretoria Energy

Flexible Layout Options To Suit Your Project

Every project is different, and your retaining wall layout needs to work with the ground conditions, not against them. Whether you’re working on a sloping site, need a consistent top level, or are incorporating curves into your design, we can help.

The green shading in the diagrams shows the consistent 100mm top thickness across all layout options, designed for a clean finish and easy integration with handrails if required.

Graphic of a stepped foundation retaining wall

Stepped Foundation With Level Top

This layout is ideal for sloping sites where a consistent wall height is needed. It allows you to follow ground levels while maintaining a straight, level finish at the top of the retaining wall.

Graphic of a sloping top retaining wall

Level Foundation With Sloping Top

This layout is perfect when you need a level foundation but want the wall to follow a changing ground profile. The top of the wall steps down gradually, making it a great fit for landscaped banks or tiered sites.

Graphic of a concave precast retaining wall

External Radius (Concave Wall)

This layout is for retaining walls that need to curve outward, commonly used around roads, raised areas, or landscaping features. All radius walls are custom-made, and we’ll work with you to get the design and dimensions right for your project.

Graphic of a convex precast retaining wall

Internal Radius (Convex Wall)

This layout is designed for retaining walls that curve inward, typically used when space is tight or when the wall wraps around a recessed area. We’ll help you get the right radius for your layout and loading requirements.

Graphic of a precast retaining wall corner unit

Precast Corner Units

Available in 90° and 45°, in single or split formats. Designed to create continuous layouts without site cutting or custom fabrication.

Icon of handrail fixing to precast retaining wall

Handrail Compatibility

DLF10GS units have a consistent 100mm top thickness, making them perfect for temporary edge protection or pedestrian handrails where required.

Stonebox gabion retaining wall render

StoneboxTM Option

Available as a hybrid wall with a gabion-style facade. Ideal for public spaces and architectural applications where finish matters.

The Company We Keep

Heavy-duty performance. Lighter environmental impact

We manufacture DLF10GS using smart processes that reduce carbon, waste and excess material use.
    • Leaner geometry reduces concrete volume per unit
    • Reduced-cement self-compacting mix for cleaner production and better finish
    • 75% recycled water in production
    • Reinforcement only where structurally needed
    • Factory powered in part by on-site renewables
Wind turbine in precast concrete factory

Your Technical Hub, Ready To Download

From CAD files and structural calculations to technical datasheets and installation guides – everything you need to specify and install our retaining walls is ready when you are.

Need a quick quote? Fill in the details below, and we’ll get back to you within 24 hours.

    Your Details


    Who should we contact?


    Where should we send pricing?


    In case we need to clarify anything.

    Project Information


    A few details is enough to get started.

    Here are some of the most common questions we’re asked about the DlF10GS wall system

    It has the same overall geometry as the CLF but with additional reinforcement to handle a surcharge capacity of up to 25 kN/m². This makes it the preferred option for HGV yards, flood defences, bund walls, and other high‑load applications.

    The standard design accommodates up to 25 kN/m², suitable for HGV loading areas, retained roads, and large‑scale storage bays.

    Yes. A heel extends the base on one side of the wall, spreading the load over a larger area. This is useful for sites with lower bearing capacity or where you want to reduce foundation depth. The heel can face either the retained or exposed side, depending on the application.

    Not necessarily. On good ground, you can install on a compacted base with a sand/cement blinding. For heavy loads, poor ground, or non-heeled walls, a reinforced concrete base may be specified by the project engineer.

    We offer 17 standard heights, from 0.5 m to 4.5 m, in 250 mm increments. Corner units are also available for all heights.

    Standard design life is 50 years under normal exposure classes (XC4, XD1, XS1, XF3). If you need longer, we can look at bespoke engineering solutions.

    Yes, you can add the Stonebox for a decorative or natural stone appearance.

    CE Mark Logo
    Benor Logo
    Boxed KOMO Logo
    Scroll to Top