The DLF10GS is our most robust L-shaped retaining wall system, designed to withstand higher loads and harsher conditions.
Quick to install and simple to use, the DLF10GS delivers outstanding performance without overengineering.
With a surcharge capacity of up to 25 kN/m², it’s ideal for projects where strength matters – from retained access roads to flood protection schemes and large-scale residential developments.
- Rapid installation – up to 80 metres per day with a standard team and lifting equipment
- Easy to install – units are delivered ready to place with no fixings or drilling required
- 25 kN/m² surcharge capacity – designed for heavy-duty performance without increasing wall thickness.
- HGV loading compatible – perfect for vehicle access areas, loading bays, and retained roads.
- 17 height options – ranging from 0.5m to 4.5m in 250mm increments, with heeled versions available.
- Reliable stock availability – with fast quoting and short lead times.
- Eurocode compliant – designed to EN 1990, 1991, 1992 and 1997; CE marked to EN 15258
See The DLF10GS From Every Angle
Our 3D renders let you explore key features of the precast retaining walls, including lifting points, tongue-and-groove joints, chamfered edges and the bevelled top.
Rotate, zoom, and inspect the product in detail before you specify or buy.
Click the 3D button to launch the interactive product viewer
Smarter Details That Make Your Job Easier
Bevelled 100mm Top
For clean visual lines and secure handrail installation
Chamfered Edges
For neat, easy joint sealing in bunds and clamps
Tongue & Groove Joint
For faster alignment and improved wall continuity
Self-Compacting Concrete
For a smooth, consistent honeycomb-free finish
Cast-In Lifting Anchors
For safe, quick and predictable handling
DLF10GS(Z) Retaining Wall With Heel
Our heeled variant is ideal for lower bearing capacity sites or variable ground conditions. Explore the rear heel detail in this interactive 3D model to understand how it spreads load more effectively.
View product features, heel extension, and overall geometry in full detail.
Click the 3D button to launch the interactive product viewer
Built For Groundworks, Backed By Engineering
We’ve taken everything that matters on site – installation speed, product quality, and structural performance and refined the design to make your job easier. DLF10GS gives you a smarter way to build retaining walls, with the engineering detail to back it up.
DLF10GS Retaining Wall - Technical Specification
| Surcharge Capacity | 25 kN/m2 |
| Design Life | 50 Years |
| Concrete Grade | C60/75 (self-compacting) |
| Exposure Classes | XC4, XD3, XS3, XF4 (EN 206), others available on request |
| Reinforcement | B500B as standard, alternative grades available on request |
| Unit Weight | Varies by height and length - see product datasheets |
| Finish | Smooth mould finish to all visible faces, with chamfered and bevelled edges |
| Connection | Tongue and groove, no fixings needed |
| Installation Speed | Typically installed at 80m/day with a 3-person team |
| Certification | CE marked (EN 15258) |
Groundworks & Civils Projects
Residential Developments
Landscaping Projects
The DLF10GS Product Range
- Units listed below are 2m long, they are also available in 1m lengths if lighter units are required.
- Corner sections are available across the full height range.
- For dimensions, weights and details on heeled variants CLF10GS(Z), please refer to the relevant datasheets below.
| Product Code | Height (mm) | Length (mm) | Width (mm) | Weight (kg) | Lifting Shackles |
|---|---|---|---|---|---|
| CLF10GS 50x200 | 500 | 2000 | 350 | 385 | 2 x 2.5T |
| CLF10GS 75x200 | 750 | 2000 | 600 | 625 | 2 x 2.5T |
| CLF10GS 100x200 | 1000 | 2000 | 600 | 745 | 2 x 2.5T |
| CLF10GS 125x200 | 1250 | 2000 | 850 | 995 | 2 x 2.5T |
| CLF10GS 150x200 | 1500 | 2000 | 850 | 1115 | 2 x 2.5T |
| DLF10GS 175x200 | 1750 | 2000 | 1150 | 1560 | 2 x 2.5T |
| DLF10GS 200x200 | 2000 | 2000 | 1150 | 1685 | 2 x 2.5T |
| DLF10GS 225x200 | 2250 | 2000 | 1350 | 2330 | 2 x 2.5T |
| DLF10GS 250x200 | 2500 | 2000 | 1350 | 2445 | 2 x 2.5T |
| DLF10GS 275x200 | 2750 | 2000 | 1600 | 3090 | 2 x 2.5T |
| DLF10GS 300x200 | 3000 | 2000 | 1600 | 3210 | 2 x 2.5T |
| DLF10GS 325x200 | 3250 | 2000 | 1850 | 3990 | 2 x 5T |
| DLF10GS 350x200 | 3500 | 2000 | 1850 | 4110 | 2 x 5T |
| DLF10GS 375x200 | 3750 | 2000 | 2100 | 5225 | 2 x 5T |
| DLF10GS 400x200 | 4000 | 2000 | 2100 | 5375 | 2 x 5T |
| DLF10GS 425x200 | 4250 | 2000 | 2350 | 6685 | 2 x 10T |
| DLF10GS 450x200 | 4500 | 2000 | 2350 | 6810 | 2 x 10T |
We had just under 800 metres of precast retaining walls delivered to site within a short period. The quality of the units is excellent, with a very consistent finish. A job well done in tight time constraints.
Steve Ripley – Pretoria Energy
Flexible Layout Options To Suit Your Project
Every project is different, and your retaining wall layout needs to work with the ground conditions, not against them. Whether you’re working on a sloping site, need a consistent top level, or are incorporating curves into your design, we can help.
The green shading in the diagrams shows the consistent 100mm top thickness across all layout options, designed for a clean finish and easy integration with handrails if required.
Stepped Foundation With Level Top
This layout is ideal for sloping sites where a consistent wall height is needed. It allows you to follow ground levels while maintaining a straight, level finish at the top of the retaining wall.
Level Foundation With Sloping Top
This layout is perfect when you need a level foundation but want the wall to follow a changing ground profile. The top of the wall steps down gradually, making it a great fit for landscaped banks or tiered sites.
External Radius (Concave Wall)
This layout is for retaining walls that need to curve outward, commonly used around roads, raised areas, or landscaping features. All radius walls are custom-made, and we’ll work with you to get the design and dimensions right for your project.
Internal Radius (Convex Wall)
This layout is designed for retaining walls that curve inward, typically used when space is tight or when the wall wraps around a recessed area. We’ll help you get the right radius for your layout and loading requirements.
Precast Corner Units
Available in 90° and 45°, in single or split formats. Designed to create continuous layouts without site cutting or custom fabrication.
Handrail Compatibility
DLF10GS units have a consistent 100mm top thickness, making them perfect for temporary edge protection or pedestrian handrails where required.
StoneboxTM Option
Available as a hybrid wall with a gabion-style facade. Ideal for public spaces and architectural applications where finish matters.
The Company We Keep
Heavy-duty performance. Lighter environmental impact
-
- Leaner geometry reduces concrete volume per unit
-
- Reduced-cement self-compacting mix for cleaner production and better finish
-
- 75% recycled water in production
-
- Reinforcement only where structurally needed
-
- Factory powered in part by on-site renewables
Your Technical Hub, Ready To Download
From CAD files and structural calculations to technical datasheets and installation guides – everything you need to specify and install our retaining walls is ready when you are.
Need a quick quote? Fill in the details below, and we’ll get back to you within 24 hours.
Here are some of the most common questions we’re asked about the DlF10GS wall system
What makes the DLF10GS different from the CLF10GS?
It has the same overall geometry as the CLF but with additional reinforcement to handle a surcharge capacity of up to 25 kN/m². This makes it the preferred option for HGV yards, flood defences, bund walls, and other high‑load applications.
What surcharge can the DLF10GS handle?
The standard design accommodates up to 25 kN/m², suitable for HGV loading areas, retained roads, and large‑scale storage bays.
Can I choose a heeled or non-heeled version?
Yes. A heel extends the base on one side of the wall, spreading the load over a larger area. This is useful for sites with lower bearing capacity or where you want to reduce foundation depth. The heel can face either the retained or exposed side, depending on the application.
Do I always need a concrete foundation?
Not necessarily. On good ground, you can install on a compacted base with a sand/cement blinding. For heavy loads, poor ground, or non-heeled walls, a reinforced concrete base may be specified by the project engineer.
What heights are available to choose from?
We offer 17 standard heights, from 0.5 m to 4.5 m, in 250 mm increments. Corner units are also available for all heights.
What’s the design life?
Standard design life is 50 years under normal exposure classes (XC4, XD1, XS1, XF3). If you need longer, we can look at bespoke engineering solutions.
Is the DLF compatible with the Stonebox system?
Yes, you can add the Stonebox for a decorative or natural stone appearance.