CLF10GS Cantilever Retaining Walls

A faster, fix-free approach to cantilever retaining wall construction.

Rethinking cantilever retaining wall construction.

Traditional precast retaining wall systems often rely on drill-and-fix methods and multiple construction stages before the wall becomes fully operational.

Our L-shape retaining wall system removes those steps entirely, helping contractors, developers and engineers reduce installation time, simplify delivery, and reduce site risks associated with drilling, including exposure to HAVS and airborne silica dust.

Quotes are available for both supply-only and full supply & install projects across the UK.

  • Fast to install – up to 80 metres a day with a three-person team and standard lifting kit
  • No fixings, no drilling – cleaner placement with no dust, no HAVS risk, and fewer delays
  • 17 height options – from 0.5m to 4.5m in 250mm increments, ready to go
  • Strong stock availability – with fast quotes and quick delivery to site
  • Flexible layout design – corners, curves, sloping tops and a hybrid gabion finish
  • Eurocode compliant & CE marked – designed to Parts 0, 1, 2 and 7; certified to EN 15258
  • Engineered for efficiency – less concrete, cement and steel, and easier to handle on site

See how the CLF system simplifies retaining wall construction.

The CLF system integrates the toe, stem and heel into a single precast unit, removing the need for drilled fixings, structural connections and multiple on-site installation stages.

Interlocking joints help guide alignment during installation, while cast-in lifting points and longer unit lengths help reduce handling, lifting and installation time.

Explore the system in 3D to see how the CLF retaining wall system simplifies cantilever retaining wall construction.

Click the 3D button to launch the interactive product viewer

Small Details. Big Impact On Site.

Annotated render of CLF10GS precast retaining wall
Icon for bevelled top edge on precast retaining walls

Faster Handrail Installation

A bevelled 100mm top edge creates clean visual lines and simplifies handrail fixing on site.

Icon for chamfered wall edges

Cleaner Joint Sealing

Chamfered edges improve mastic application and reduce damage to bund walls and silage clamps.

Icon for interlocking concrete wall joints

Faster Wall Alignment

Interlocking tongue-and-groove joints help to guide alignment and improve consistency across long wall runs.

Icon for product quality

More Consistent Finishes

Self-compacting concrete improves surface quality and reduces the risk of honeycombing and other visible defects.

Icon for cast-in pin anchors

Safer, Faster Handling

Cast-in lifting anchors help simplify lifting operations and improve on-site installation efficiency.

CLF10GS(Z) Retaining Wall With Heel

Our heeled cantilever retaining wall system is designed for sites with low bearing capacity, variable ground conditions, or projects requiring additional stability.

By extending the base geometry, the heel helps spread loads more effectively, improve stability and reduce bearing pressure without relying on additional fixings or anchors.

Explore the 3D model to see how the integrated heel detail supports different site conditions while maintaining the same fix-free installation approach.

Click the 3D button to launch the interactive product viewer

Built For Groundworks, Backed By Engineering

We’ve refined the CLF system around the realities of modern construction – reducing installation stages, simplifying handling and improving consistency on site without compromising structural performance.

The result is a cantilever retaining wall system that’s faster to install, easier to coordinate and supported by proven engineering principles.

Warehouse construction precast retaining walls

Engineered for site performance

The CLF system combines fix-free installation with proven cantilever retaining wall engineering, high-strength self-compacting concrete and factory-controlled manufacturing. The result is a retaining wall system designed for consistent performance both structurally and practically on site.

Surcharge Capacity 10 kN/m2
Design Life 50 Years
Concrete Grade C60/75 (self-compacting)
Exposure Classes XC4, XD3, XS3, XF4 (EN 206), others available on request
Reinforcement B500B as standard, alternative grades available on request
Unit Weight Varies by height and length - see product datasheets
Finish Smooth mould finish to visible faces with chamfered and bevelled edges as standard
Connection Interlocking tongue and groove, no structural fixings required
Installation Speed Up to 80m/day with a 3-person team and standard lifting equipment
Certification CE marked (EN 15258)

Proven across a wide range of retaining wall projects

The CLF system is used across a wide range of retaining wall applications where installation speed, reduced site operations and long-term performance are important.

From groundworks and residential developments to commercial landscaping and infrastructure projects, the system is designed to simplify retaining wall construction across a range of site conditions and project requirements.

CLF10GS Product Range

  • Units are available in a wide range of standard heights, with 2m long units offered as standard and 1m lengths available where lighter lifts or restricted access are required.
  • Selected units with * are also available in 4m lengths to reduce the number of lifts, joints and installation time on larger retaining wall projects.
  • Corner units are available across the full height range, while heeled variants (CLF10GS(Z)) offer additional stability for sites with low bearing capacity or variable ground conditions.
  • Download the relevant datasheets below for detailed dimensions, unit weights and technical details.
Residential retaining walls from CBS
Product Code Height (mm) Length (mm) Width (mm) Weight (kg) Lifting Shackles Datasheet
*CLF10GS 50x200 500 2000 350 385 2 x 2.5T
*CLF10GS 75x200 750 2000 600 625 2 x 2.5T
*CLF10GS 100x200 1000 2000 600 745 2 x 2.5T
*CLF10GS 125x200 1250 2000 850 995 2 x 2.5T
*CLF10GS 150x200 1500 2000 850 1115 2 x 2.5T
*CLF10GS 175x200 1750 2000 1150 1545 2 x 2.5T
*CLF10GS 200x200 2000 2000 1150 1665 2 x 2.5T
CLF10GS 225x200 2250 2000 1350 2300 2 x 2.5T
CLF10GS 250x200 2500 2000 1350 2425 2 x 2.5T
CLF10GS 275x200 2750 2000 1600 3175 2 x 2.5T
CLF10GS 300x200 3000 2000 1600 3175 2 x 2.5T
CLF10GS 325x200 3250 2000 1850 3940 2 x 5T
CLF10GS 350x200 3500 2000 1850 4060 2 x 5T
CLF10GS 375x200 3750 2000 2100 5190 2 x 5T
CLF10GS 400x200 4000 2000 2100 5310 2 x 5T
CLF10GS 425x200 4250 2000 2350 6605 2 x 10T
CLF10GS 450x200 4500 2000 2350 6725 2 x 10T

Working on a split-level site is always challenging, and late design changes required more retaining wall foundations than were initially planned. This was a test for us to keep everything on track for the University at a critical stage, and meant they had to be very flexible indeed. We’ve been very impressed with the team, who were committed to delivering a quality job.

Mike McCormick – Bouygues

Designed to work in all site conditions

Every retaining wall project is different. Ground levels, layouts, loading requirements and site constraints all influence how the wall needs to work in practice.

The CLF system is designed to accommodate stepped foundations, sloping top profiles, curves, corners and handrail integration while maintaining the same fix-free installation approach across the system.

Graphic of a stepped foundation retaining wall

Stepped Foundation With Level Top

Ideal for sloping sites where a consistent retaining wall height and clean top line are required.

Graphic of a sloping top retaining wall

Level Foundation With Sloping Top

Allows the retaining wall to follow changing ground levels while maintaining a level foundation.

Graphic of a concave precast retaining wall

External Radius (Concave Wall)

Custom curved retaining walls designed for roads, landscaped areas and non-linear layouts.

Graphic of a convex precast retaining wall

Internal Radius (Convex Wall)

Designed for tighter layouts and recessed retaining wall applications where internal curves are required.

Graphic of a precast retaining wall corner unit

Precast Corner Units

Available in 90° and 45° configurations to simplify corners without site cutting or modification.

Icon of handrail fixing to precast retaining wall

Handrail Compatibility

Consistent 100mm top thickness simplifies temporary edge protection and permanent handrail installation.

Stonebox gabion retaining wall render

StoneboxTM Option

Hybrid retaining wall finish combining structural precast concrete with a gabion-style architectural facade.

The Company We Keep

Reducing material use without compromising performance

The CLF system is designed to reduce unnecessary material use through leaner geometry, efficient reinforcement design and factory-controlled production methods.

Combined with reduced-cement self-compacting concrete and recycled process water, this results in a retaining wall system that reduces waste and improves production efficiency without compromising structural performance.

  • Leaner geometry helps reduce concrete volume per unit
  • Reduced-cement self-compacting concrete mix
  • 75% recycled water used in production
  • Reinforcement placed only where structurally required
  • Factory operations partially supported by on-site renewables
Riverside retaining walls from CBS

Technical information ready when you need it

From CAD drawings and structural calculations to installation guidance and technical datasheets, everything needed to specify, price and install the CLF precast retaining wall system is available to download.

Clear technical information is ready to support your project from early design through to on-site installation.

Tell us about your retaining wall project

    Your Details


    Who should we contact?


    Where should we send pricing?


    In case we need to clarify anything.

    Project Information


    A few details is enough to get started.

    Common questions about the CLF retaining wall system

    No, the CLF units are designed for fix-free installation – no bolts, bars, or grout needed in most cases. Their shape, weight, and interlocking joints keep everything securely in place. It’s one of the biggest time and money savers our customers appreciate.

    You’ll need lifting equipment compatible with DEHA shackles. A telehandler or excavator with a lifting chain is suitable for most sites. Units up to 2.5 m are delivered upright, so there’s no need to rotate them before installation.

    Not always. If your site has good ground conditions with standard loadings and surcharge, you can install on a compacted base with a sand/cement blinding layer. For heavier loads or poor ground conditions, your engineer may specify a poured concrete base. We’re happy to supply the relevant product information to help with the design.

    We supply precast internal corners where the base toes overlap. For external corners, the units are simply aligned side by side on site. Standard angles are 90° and 45°, but we can also cast custom angles to suit your layout.

    CLF10GS walls are available in 17 heights ranging from 500mm to 4m. Standard lengths are 2m, but we also offer 1m units suitable for tighter spaces and 4m units ideal for low-level walls – great for reducing lifts and joints.

    Yes. Sloping top units are cast to order, and handrails can be fixed on site using chemical anchors (which we recommend over mechanical fixings to prevent cracking). We don’t cast fixings in – it gives you more flexibility on site.

    We keep standard sizes in stock, so we can usually deliver within a week. Sloping tops, custom heights, and decorative finishes are made to order – lead time is typically 2–4 weeks for these units.

    CE Mark Logo
    Benor Logo
    Boxed KOMO Logo
    Scroll to Top